Construction & Permitting

Upload permits, inspection reports, change orders, and invoices. SaralFlow tracks approvals, blockers, and budget impact.

Sample · Demo data
Construction & Permitting

Sample packet

Permit / project status packet

Sample project · 428 Oak Ave commercial addition (fictional)

Needs more documents4 supporting documents still recommended for a complete packet.

Executive summary

What happened, what matters, and what to do next — from documents SaralFlow reviewed.

Building permit #BP-2026-1142 active — 2,400 sq ft commercial addition in progress.

Framing inspection passed April 8; electrical rough-in failed April 12 with 3 deficiencies.

City fire suppression requirement added April 10 — not in original scope or approved budget.

3 approved change orders total +$52,800; April billings $64,200 on track to revised contract $472,800.

Estimated schedule delay 2–3 weeks until electrical re-inspection and fire suppression scope resolved.

Key findings

  • Project summary: 428 Oak Ave commercial addition · permit #BP-2026-1142 · 2,400 sq ft
  • Permit status: framing passed Apr 8 · electrical failed Apr 12 · plumbing not scheduled
  • Inspection blockers: 3 electrical deficiencies — junction box, GFCI, panel labeling
  • Change-order evidence: CO #3 HVAC +$18,400 approved · total COs +$52,800
  • City blocker: fire suppression requirement added Apr 10 — not in original scope/budget
  • Cost evidence: April billings $64,200 matched to approved scope
  • Schedule impact: 2–3 week delay until electrical re-inspection and fire suppression estimate

Timeline

  1. 2026-03-01Permit issued

    Permit #BP-2026-1142 — stamped plans approved

  2. 2026-04-08Framing passed

    Inspector J. Park sign-off

  3. 2026-04-12Electrical failed

    3 deficiencies — re-inspection required

  4. 2026-04-10City requirement

    Fire suppression system added to scope

Output sections

Permit status

  • Permit #BP-2026-1142: Active
  • Framing: Passed ✓ (Apr 8)
  • Electrical rough-in: Failed ⚠ (Apr 12)
  • Plumbing: Not yet scheduled

Blocking items

  • Electrical: 3 deficiencies — correct and re-inspect
  • Fire suppression: Add to scope, get estimate
  • Re-inspection needed before insulation/drywall
  • Estimated delay: 2–3 weeks

Budget & change orders

  • Original contract: $420,000
  • Approved change orders: +$52,800
  • Current contract: $472,800
  • April billed: $64,200 (on track)

Next steps

  • Fix 3 electrical deficiencies
  • Schedule electrical re-inspection
  • Get fire suppression estimate for CO #4
  • Update project schedule with 2-week delay

Source evidence

  • Building permit application — 428 Oak Ave Confirmed
  • Architectural plans — rev 3 Confirmed
  • City inspection report — Framing Confirmed
  • City inspection report — Electrical rough-in Needs review
  • Change order #3 — HVAC upgrade Confirmed
  • Contractor invoices — April (4 invoices) Confirmed
  • City requirement letter — fire suppression Needs review

Documents reviewed

Building permit application — 428 Oak Ave

Confirmed

Permit Application

Permit #BP-2026-1142 · commercial addition · 2,400 sq ft

Architectural plans — rev 3

Confirmed

Plans

Stamped plans · structural, electrical, plumbing included

City inspection report — Framing

Confirmed

Inspection Report

Framing inspection passed April 8 · signed by inspector J. Park

City inspection report — Electrical rough-in

Needs review

Inspection Report

Electrical inspection failed April 12 — 3 deficiencies noted

Change order #3 — HVAC upgrade

Confirmed

Change Order

CO #3: +$18,400 · approved by owner April 5

Contractor invoices — April (4 invoices)

Confirmed

Invoices

Total billed April: $64,200 · matched to approved scope

City requirement letter — fire suppression

Needs review

Requirement

City requires fire suppression system — not in original scope or budget

Issues needing review

Electrical rough-in failed — 3 deficiencies — Inspector J. Park failed electrical April 12. Deficiencies: exposed junction box, missing ground fault, panel labeling incomplete. Re-inspection after corrections.

Fire suppression not in original scope — City requirement letter dated April 10 adds fire suppression. Estimate needed — this may require a budget revision and change order #4.

Framing inspection passed — Framing signed off April 8. Can proceed with insulation and drywall after electrical clearance.

Missing documents

  • Electrical rough-in: Failed ⚠ (Apr 12)
  • Re-inspection needed before insulation/drywall
  • Fire suppression system estimate — required for Change Order #4 and city compliance before rough-in sign-off
  • Electrical correction photos/sign-off — re-inspection cannot be scheduled until 3 deficiencies documented as fixed

Recommended next actions

Fix 3 electrical deficiencies

Fix 3 electrical deficiencies

Schedule electrical re-inspection

Schedule electrical re-inspection

Get fire suppression estimate for CO #4

Get fire suppression estimate for CO #4

Update project schedule with 2-week delay

Update project schedule with 2-week delay

Sample · Demo data — fictional construction project (428 Oak Ave). Not legal or contracting advice.